Electro Warmflo Temperature Sensing Boiler with Dual Fuel

The Electro Electro-Boiler Midsize "MA, MO" Series is the most deluxe model that is designed for multiple temperature and zoning applications. This model has the ability to sense water temperature and maintain an accurate boiler temperature output by only energizing the electric elements for needed output (not full capacity). To learn more about this concept read WarmFlo. This model eliminates extra costs associated with relays, extra temperature controls, zone boxes, etc. Our more experienced installers use this boiler to avoid the extra cost of the above.


Our front panel temperature  knob allows you to simply dial in your desired output temperature and the TS will automatically adjust to meet your water temperature needs.  Available in 10-20 kW, single phase 240V.


Available Models:

240V single phase, w/ temperature setting dial, no outdoor reset


Model#
kW
Btu/h
Amps
Breakers
EB-MA-10
10
34,000
42
60
EB-MA-15
15
51,000
63
60,30
EB-MA-20
20
68,000
83
60,60

240V single phase, w/ temperature setting dial, outdoor reset


Model#
kW
Btu/h
Amps
Breakers
EB-MO-10
10
34,000
42
60
EB-MO-15
15
51,000
63
60,30
EB-MO-20
20
68,000
83
60,60

Other Benefits
  • Built-in temperature/pressure gauge
  • High Mass/Low Mass element modulation
  • Boiler status panel
  • ASME/CSA US/Canada certification
  • Complete front panel accessibility
  • Dual Boiler option
  • Load Management connection
  • Super quiet operation
  • 20-year element/vessel warranty
 

Available Literature/
Specification Sheets

BL002 Radiant Applications
BL006  Electro-Boiler Literature
BL509TS Series Midsize Specification Sheet
Electro-Boiler Warranty Statement
 

Thursday, January 2, 2014

Electric Space Heaters and how to size one properly

During a cold weather spell you may need to subsidize your heating with an electric space heater. Do you have a drafty room or need to add heat just to help keep your pipes from freezing or have an area that does not have enough BTU's from you current heating system?  If so, do you know how to size a unit for your application?  The following information will help:

How to properly size an electric heater:

1) Measure the length and width of the room to determine total square footage.
2) Select your level of insulation
Poor - Little insulation (Older homes) - 12.5 watts per foot
Average - R-11 in walls and R-19 in ceiling - 10 watts per square foot
•Full - R-19 in walls and R-38 in ceiling - 7.5 watts per square foot
3) Make adjustments as necessary.
•For ceilings above 8 feet - increase wattage by 25% for every additional 2 feet in height
•Use a minimum of 1000 watts in a bathroom
•If a recommended wattage falls between two sizes - select the large heater
•For colder climates (prolonged winter temperatures below 20°F) use the next higher wattage up to 15 watts per square foot
4)  Use the chart below to calculate the recommended wattage or calculate it yourself with this example:
A room that is 10 feet wide by 13 feet wide with an 8 foot ceiling and Average insulations =  10 x 13 = 130 then 130 x 10 watts/per square foot = 1300 Watts



Room Size
(Sq Ft with 8 foot ceiling)

Watts
(Poor Insulation)

Watts
(Avg Insulation)

Watts
(Fully Insulation)

20 square feet

250

250

250

40 square feet

500

500

500

60 square feet

750

750

450

80 square feet

1000

1000

750

100 square feet

1250

1000

750

120 square feet

1500

1250

1000

140 square feet

1750

1500

1250

160 square feet

2000

1750

1250

180 square feet

2250

2000

1500

200 square feet

2500

2000

1500

220 square feet

2750

2250

1750

240 square feet

3000

2400

2000


Please Note: All these numbers are for general information - each install will vary depending on many other fact

To calculate the Watts to BTU click on the link below....

http://www.houseneeds.com/learning-center/electric-space-heater-install-information/watts-to-btu-calculator
 
For product information go to the below link to select the heater that will meet your needs.
 
 
Or call us at 866-432-8123 ask for sales

Thursday, December 19, 2013

Electro Mini-Boiler WarmFlo H Series


This model is designed for multiple temperature and zoning applications. This model has the ability to sense water temperature and maintain an accurate boiler temperature output by only energizing the electric elements for needed output (not full capacity). To learn more about this concept read WarmFlo. This model eliminates extra costs associated with relays, extra temperature controls, zone boxes, etc. Our more experienced installers use this boiler to avoid the extra cost of the above components.

Models Available:



Model #

Volts


Watts


Amps


kW


Phase


Btu/h


CB


EMB-H-5


240


4,500


18.75


4.5


1-60


15,358


30A


EMB-H-7


240


7,000


29.17


7


1-60


23,891


45A

EMB-H-9


240


9,000


37.5


9


1-60


30,717


60A


BL308Mini-Boiler Literature
BL006Electro-Boiler Literature
BL001Boiler Accessories
BL003Radiant Floor Heating
BL306Mini-Boiler Specification Sheet
Electro-Boiler Warranty Statement

Features include:
  • Easy installation
  • WarmFlo sensing technology
  • Built-in pump control relay
  • Pressure temperature gauge
  • Built-in load management
  • Wall-mounted design
  • Two level hi-limit protection-160° pipe protection
  • Quiet operation
  • 20-year element/vessel warranty
  • 100% efficient

 
Typical radiant applications include:
  • Multi-zone applications
  • Multi-temperature applications
  • Hot water baseboard/radiator systems
  • In-floor heat - staple-up application
  • Forced air hot water coil
  • Apartments
  • Condo’s
  • Garages
  • Shops
  • Animal Barns
  • Whole house by using one boiler per level
  • Even Bus Shelters....
Give us a call at 866-432-8123 if you have any questions or to place an order.