Steibel-Eltron Electric Convection Heater - CNS 50 E - 231542 is a modern surface-mounted convection heater with a sleek European slimline design. CNS-E units are an effective, efficient replacement for traditional baseboard heaters, using significantly less room to accomplish the same heating task.
With its built-in thermostat, a single CNS 50 E is perfect as a stand-alone heating system in bathrooms or small rooms. Multiple CNS-E units can be placed strategically in larger spaces and their temperature settings adjusted individually for maximum comfort control. If used to replace an existing heater with a separate wall-mounted thermostat control, CNS-E heaters may be wired to use that control. Overheat protection is built into the unit.
CNS-E heaters work through natural convection, ensuring draft-free operation. Cool room air flows in the bottom of the unit, is warmed by the heating element, and rises silently out the top to heat the room. The CNS 50 E is designed with a frost protection setting. The lowest thermostat setting will maintain the room above freezing temperatures.
Like all of Stiebel Eltron's products the CNS 50 E series of heaters have an outstanding reliability record. Our three year limited parts warranty is a testament to the confidence we have in our products.
Econo Heater - Electric Panel Heaters offer out-of-the-way wall mounting and is an economic way of providing efficient electric room heating at a low cost. The new style has the on/off switch on the back right side of the unit to give our new Panel Heaters a sleeker look. Also, the panel heaters have rounded edges.
Using convection technology, heat is mainly generated behind the heater in the space between the panel and the wall, which leads to an efficient up-draft of heat circulated into the room. Econo heaters principle of convection means that about 90% of the heat comes from the back of the panel, while only 10% is radiated from the front of the panel. This form of electric "background" heating is not only very economic, but also safe and efficient.
Electrical Baseboard Heaters / Electric Baseboard Heaters in 120 Volt & 220/240 Volts. Use Electrical Space and Room Heaters by Qmark Marley. Available Electrical Baseboard installed on walls or Electrical Portable Baseboard Heaters. Your choice. Entire range of Electrical Voltage Thermostats too.
Myson Electric Towel Warmers / Electric Towel Heaters Economical and efficient, a Myson Electric towel warmer is a decorative source of heat that will add comfort to the room as well as keeping your towels warm and dry.
Throughout this section you’ll discover a variety of elegant and fashionable designer towel warmers in our European, Contemporary, Classic and Gem Collections, all coupled with advanced technology to provide efficient and environmentally friendly ways to deliver heat with function and style.
What Size Electric Heater do I need? Click here to see.
For all our Electric Products please click here.
Please call with questions at 866-432-8123
Solutions gathered by Houseneeds.com for Solar Heating, Hydronic Heating Systems, Hot Water Heating Systems, PEX Tubing Layouts, PEX Radiant Heating Systems, Underfloor Radiant Heat, Slab Radiant Heat, Hot Water Boilers Configurations and more.
Thursday, September 18, 2014
Thursday, September 11, 2014
How to Fill and Purge your Hydronic Heating Systems
A properly plumbed hydronic heating system makes it easy to add water and remove air, during the initial fill / purge and in later servicing.
We remove all of the air to make the hydronic heating system work mechanically correct. Small amounts of air can cause gurgling noises and large amounts of air can cavitate the circulators pumps causing the heating loop to stop flowing, resulting in a lack of heat.
When filling or purging a hydronic heating system, it is easiest when the system is broken down into smaller sections or loops. Each loop / zone is connected to the hydronic boiler fill valve and has the ability to be isolated from the other loops. Ball valves and drains isolate the system.
Water is introduced into the hydronic system in one way, flowing down the piping and out the boiler drain, carrying the air with it.
The process of isolating and filling is repeated until the hydronic system is full of water and the air removed.
Flushing the hydronic system works in reverse, replacing the old water with new.
Flushing the hydronic system is important. The hydronic heating system should be flushed to remove and flux or solder that may be mixed in the water.

This is only an example. Actual layouts vary from job to job.
For purge valves and heating supplies please click on the below link...
http://www.houseneeds.com/heating/hydronic-heat-supplies
We remove all of the air to make the hydronic heating system work mechanically correct. Small amounts of air can cause gurgling noises and large amounts of air can cavitate the circulators pumps causing the heating loop to stop flowing, resulting in a lack of heat.
When filling or purging a hydronic heating system, it is easiest when the system is broken down into smaller sections or loops. Each loop / zone is connected to the hydronic boiler fill valve and has the ability to be isolated from the other loops. Ball valves and drains isolate the system.
Water is introduced into the hydronic system in one way, flowing down the piping and out the boiler drain, carrying the air with it.
The process of isolating and filling is repeated until the hydronic system is full of water and the air removed.
Flushing the hydronic system works in reverse, replacing the old water with new.
Flushing the hydronic system is important. The hydronic heating system should be flushed to remove and flux or solder that may be mixed in the water.
This is only an example. Actual layouts vary from job to job.
For purge valves and heating supplies please click on the below link...
http://www.houseneeds.com/heating/hydronic-heat-supplies
Thursday, August 28, 2014
Check out Houseneeds sale and clearance page
Take advantage of these cheap prices on Gas Space Heaters, Tankless Water Heaters, Hydronic Heating Supplies, Gas Boilers, Propane Boilers, Wood Stoves Accessories and more. Our Sale Items are always changing so check back often.
Sale Items at the link below....
http://www.houseneeds.com/sale
Sale Items at the link below....
http://www.houseneeds.com/sale
44 Clearance Items at the link below....
http://www.houseneeds.com/clearanceWe ship via FEDEX throughout the United States - unless otherwise noted. These products are non-returnable and carry a full warranty unless otherwise stated. Have any questions please call 866-432-8123.
Tuesday, July 22, 2014
Whole House Fans and Attic Fans
Whole House Fans, Attic Fans and Solar Attic Fans from Qmark Marley, Quiet Cool, Tamarack and HNSF. Whole House Fans and Whole House Attic Fans are a great way to keep your house cooler and save on Air Conditioner Bills.
Whole House Fans pulls heat out of your home and attic bringing in cooler outside air. Save up to 30% on your a/c bills
Quiet Cool Whole House Fans are designed to cool and vent your entire home by pulling warm up and out while drawing fresh cool air in.
Qmark Attic Fans - Marley Roof Mounted Attic Exhaust Fans in 120 Volt Electric
HNSF Solar Attic Fan - 20 Watts Adjustable Solar Pane. Solar Powered Attic Cooling Fans
Qmark Gable Attic Fans - Marley Gable Mounted Attic Exhaust Fans in 120 Volt Electric.
Eco-Breeze Fresh Air Cooling System - Window Unit - Eco-Breeze using Mother Nature to cool your rooms
Eco-friendly sun with Attci Fans that install on the Roof and Gable. You can easily, quickly and economically use the power of the sun to reduce attic heat.
Qmark Gable Attic Fans - Marley Gable Mounted Attic Exhaust Fans in 120 Volt Electric
Please call Sales at www.houseneeds.com if you have any questions about the above products at 866-432-8123.
Thursday, July 17, 2014
New Construction and PEX Radiant Heat FAQ's
1. What do I need?
To properly size most components related to your under floor heating system we highly recommend a heat loss calculation for your project if this is your primary heat source. Why? Heat loss is a critical step, as we can estimate the average output of a radiant floor at 25 to 35 BTU’s per square foot but windows, doors, insulation, and degree days all make a major impact on getting you just what you need.The most common sizing mistake with in floor heat is in oversizing. This not only makes the new radiant heating system cost more to install, but also forces it to operate inefficiently, break down more often, and cost more to operate. Oversized heating equipment also often creates uncomfortable and large temperature swings in the house plus it will short cycle the hot water boiler and run outside the design parameters costing you more money.
We are not in the business of selling equipment that you don’t need and a little work up front can save you thousands of dollars in costs over the life of your system.
2. How do I calculate my heat loss?
Have your architect or builder supply it to you as in many states like NH or CA it is required. Calculate it yourself using software - go back to the Heat Lost Calucator under Pex Tubing Radiant Installs. Or use one of the two different rough guides below.Insulation Type and Climate Zone
(Please Note: We highly recommend that you do a heat loss calculation and provide the information below as a starting place)
1) No insulation in walls, ceilings, or floors; no storm windows; windows and doors fit loosely .... 60 to 100 BTU's per Sq. Ft.
2) R-11 insulation in walls and ceilings; no insulation in floors over crawl spaces; no storm windows; doors and windows fit fairly tight .... 50 to 60 BTU's per Sq. Ft.
3) R-19 insulation in walls, R-30 in ceilings, and R-11 in floors; tight-fitting storm windows or double pane windows .... 29 to 35 BTU's per Sq. Ft.
4) "Energy Star Rated" house with R-24+ wall insulation, R-40 in ceilings, and R-19 in floor; tight-fitting storm windows or double pane windows; vapor barrier sealed carefully during construction .... 20 to 25 BTU's per Sq. Ft.
5) SIP or Earth-sheltered house with little exposure; argon filled windows, and R40+ insulated .... 10 to 15 BTU's per Sq. Feet.
Climate Zone
Heating Sq. Footage by Climate Zone for a pre-1970's HouseHouston, TX ZONE 1 --> 15 - 25 Btu's per square foot
Los Angles, CA ZONE 2 --> 25 - 30 Btu's per square foot
St. Louis, MO ZONE 3 --> 30 - 40 Btu's per square foot
New York, NY ZONE 4 --> 40 - 50 Btu's per square foot
Minneapolis, MN ZONE 4 --> 50 - 60 Btu's per square foot
Outdoor Design Temperature
The Outdoor Design Temperature (ODT), also referred to as the 2.5% design day temperature, is not the coldest day ever, but rather a temperature that is achieved 97.5% of the time.Examples:
ODT Chicago = - 8 Degree F
ODT Denver = 1 Degree F
ODT Minnesota = -12 Degree F
ODT Washington = 17Degree F
Simply multiply the appropriate factor above by your home's total heated square footage to arrive at your approximate required heating capacity. For example, if you live in Zone 3, your home is well insulated, and you have 2000 heated square feet, the equation will look like this:
2000 square feet of "Energy Star" grade new construction but with lots of windows = 35 BTU's per sq ft. is 70,000 Btu Load
Then, to calculate the output on a hot water boiler, multiply its efficiency rating by its listed input rating for the actual Btu output of heat. An example of a medium efficiency boiler. Of course, this is a very simple way to look at efficiency - but actually, it is more complicated. Factors such as, how long does it take to get to efficiency, condensing, direct vent or not, using pex and amound of water in the boiler all effect true efficiency.
87,000 Btu input X .86 efficiency = 73,000 Btu actual output
3. Existing Heating System
All hot water boilers sold in the U.S. must have a rating plate. Check the rating plate and get the:1) For Example --> 92,000 Btu Input of your Hot Water Boiler X .80 efficiency of your Boiler = 73,000 Btu actual output
2) Count the total linear footage of baseboard in the home. Multiply this number by 600 BTU’s. This will give you the BTU output at 180 Degrees F. This number should be close to the Boilers actual output.
There are a few ways to calculate heat loss. Use the above information to get a rough idea. We strongly recommend that you download a heat loss calculator. Why? Because windows and doors make a huge difference to the heat load of your home. Once you have an idea of your requirements, we will be able to get you a quote.
4. Ways to install Radiant PEX with an existing floor
PEX Tubing Under the Floor - Typically under hardwood or tile flooringPEX In Floor - Typlically in poured cement
PEX Over Floor - Typlically using ThermalBoard, VersaTherm or Creatherm Radiant Heat Mass
5. Radiant Slab on Grade
For residential slabs we recommend 1/2 Inch PEX tubing to be 12 Inch on center. Along walls with lots of glass or high heat loss the PEX should be 6 Inch to 9 Inch on center on the outside walls for the first 2 feet, and 12 Inch on center everywhere else.When figuring the over all length of tubing you will need you divide any 6 Inch spacing area by .5, divide any 9 Inch spacing area by .75 and any 12" spacing area by 1. This will give you the over all length of the PEX needed in the slab. You will need to add the length of tubing needed to get up to the pex manifold.
Typically pex manifolds are mounted 18 Inch to 24 Inch off the slab.
6. Installing PEX Tubing
Following good piping practices the maximum length of each 1/2 Inch PEX tubing runs should be no longer than 300 feet (300-foot maximum is code in many places). When the pipe loops exceed 300 feet you need to use larger circulators (pumps) to maintain this temperature drop. With larger circulators initial cost is higher and they usually require twice as much electricity to run. Most good radiant installers try to limit piping loops to below 300 feet.There are many correct ways of installing in floor heat PEX within a slab. The best way is tying the PEX to the reinforcing mesh or rebar. When attaching the PEX Tubing to wire reinforcing mesh or rebar it is recommend that a zip tie be used every 2 feet of PEX Tubing.
Another way to install PEX in a slab is attaching the PEX Tubing to ridged insulation. The use of insulation screw clips or large plastic staples is common.
We recommend an insulation screw clip or staple every 2 feet if installing the tubing over insulation only (no wire mesh). If you use 2 Inch polystyrene insulation it is recommended that you use a 6 mil. polyethylene moisture barrier.
Installing the manifolds and keeping the lines under pressure (air or water pressure) for the concrete pour is highly recommended and required by code in many locations.
7. Insulation
Insulation is always needed with any radiant heating system and especially needed under slabs. Why, if the soil has any moisture in it the moisture will wick away the heat at a tremendous rate making your system inefficient.Today many radiant slabs being installed with insulation only around the perimeter. Their belief is that you should store the heat in the ground for use later. One problem with this notion is that a large portion of the heat is absorbed into the ground and never warms your home. Why do you want to pay to heat the ground? Slab Insulation is important for the entire slab.
We recommend Slab Shield Insulation which was designed specifically for under slab applications. Manufactured using two separate layers of 1/4 Inch polyethylene foam with a pure aluminum center. This product is available in 4 Feet x 63 Feet rolls for easy application. It is simply unrolled and taped together (this is necessary for a complete vapor barrier to be achieved). With Slab-Shield there's no time wasted installing 4 Feet x 8 Feet foam boards. With a puncture resistance of 92.9psi you can work and walk on top of it without it crumbling apart.
8. Here's a rough idea of what it will cost
Below are some pricing guidelines. These numbers are higher than most proposals, but can act as a "stand-in" as you're creating your construction budget.Mid Efficiency (87%+) hot water boiler: $1,500 to $3,000
High Efficiency (95%+) hot water boiler: $2,200 to $5,500
Per zone controls: $250.00 ea. zone
Slab on grade Radiant: $1.20 per square
Wood Underfloor Radiant: $1.70 Per square
Myson radiators: $260 per 5000 BTU
People consider radiant heating for its superior economic and comfort advantages. But with energy prices rising 35%+ this year, whichever efficient system you choose, you’ll appreciate the cost savings!
To view Houseneeds products follow this link:
http://www.houseneeds.com/heating
Thursday, July 10, 2014
How to Size Copper Tees for Hydronic Heating Systems
Tees are generally measured from the "Run" to the "Bull".
The "Run" is the left-to-right or the length of the Tee.
The "Bull" is the top part of the Tee.
For example if a Tee is 3/4" X 3/4" X 1/2", then the left inside diameter is 3/4", the right inside diameter is 3/4" and the top inside diameter part is 1/2". Tees where the run and the bull are not uniform are referred to as "Reducing Tees".

Click on the product links below to view sale items:
Monoflow Tees
Copper Tees
45° Copper Elbows
90° Copper Elbows
Copper Couplings
End Caps
Sharkbite Lead Free
Copper Adapters
Boiler Drains
Baseboard Tees
Brass Fittings
The "Run" is the left-to-right or the length of the Tee.
The "Bull" is the top part of the Tee.
For example if a Tee is 3/4" X 3/4" X 1/2", then the left inside diameter is 3/4", the right inside diameter is 3/4" and the top inside diameter part is 1/2". Tees where the run and the bull are not uniform are referred to as "Reducing Tees".
Click on the product links below to view sale items:
Tuesday, June 10, 2014
Eco Breeze the Humidity and Temperature Solution
Whole-house fans were mainly popularized in the United States through the 1950s-60s as an inexpensive method to cool homes. A whole house fan uses fresh air ventilation cooling which is simple and much lower in cost than air conditioning cooling. The fan cools the house by drawing cool outdoor air inside through open windows and exhausting hot indoor air through the attic to the outside. As the outdoor temperature drops in the evening, the windows are opened and the fan is turned on. In the morning the process is reversed. The fan is turned off and the windows are closed, trapping cool air in the home and sealing out the hot day time air. Since the 1950’s, whole-house fans have been improved with insulated vent doors, quieter fans and motors, and remote controls but the fundamental manual cooling process of opening and closing of windows remains unchanged.
Eco Breeze FAQ's http://www.houseneeds.com/learning-center/house-fans-ventilation-erv-hrv-hep-filters/eco-breeze-faq
Eco Breeze – The Paradigm shift
Eco Breeze provides the same low cost fresh air ventilation cooling in a completely different way. The result is reduced fan noise, convenient operation, lower installation cost, and improved comfort.
Monitors outside temperature and humidity – No more humid air
High humidity makes us uncomfortable and makes air conditioners work harder to remove moisture. Eco Breeze monitors outdoor humidity and only provides fresh air cooling when the outside air is dry and cool.
Individual room cooling – Quiet operation
Eco Breeze is designed to cool individual rooms rather than the whole-house. This produces the same air tangential fanchanges as a whole house fan yet requires a fraction of the air flow. The lower air flow and the use of tangential blowers makes the unit significantly quieter than a whole-house fan. The fan power is also a fraction of a whole house fan resulting in energy savings even when multiple fans are installed in a home.
Simple Installation – No holes to the attic – No Installation cost
The Eco Breeze installation is simple and can be done in minutes. It installs in a window and does not require cutting holes to access an attic, the addition of attic ventilation openings or the addition of electrical wiring.
Automated Operation – No windows to open and close
Eco Breeze exhausts the hot air to the outdoors and also brings the cool air into a room. The louvers automatically open to provide cooling and automatically close to seal the cool air inside ending the daily routine of opening and closing windows.
Seamless integration with air conditioning – No need to turn off the air conditioner
Eco Breeze monitors the indoor temperature and humidity and will only bring in the outside air if it is lower in temperature and humidity. The air conditioner thermostat will sense the cooler air and keep the air conditioner off.
Optimum use of Fresh Air Cooling – No more guessing
Eco Breeze has a dynamic temperature and humidity sensing system that automatically uses outside fresh air for cooling any time that it is available. In midsummer fresh air cooling may be available for a few hours a day in the late night and early morning in even the hottest regions. Eco Breeze will automatically save money even when you are sleeping. In the other seasons, Eco Breeze can operate mornings, evenings, and nights, and sometimes sizeable parts of the daytime.
Rain Guard System – No wet floors
Eco Breeze has a unique rain guard to prevent rain from blowing into your room even when it is operating. This completely eliminates the hassle of closing windows during rain storms.
Eco Breeze provides the same low cost fresh air ventilation cooling in a completely different way. The result is reduced fan noise, convenient operation, lower installation cost, and improved comfort.
Monitors outside temperature and humidity – No more humid air
High humidity makes us uncomfortable and makes air conditioners work harder to remove moisture. Eco Breeze monitors outdoor humidity and only provides fresh air cooling when the outside air is dry and cool.
Individual room cooling – Quiet operation
Eco Breeze is designed to cool individual rooms rather than the whole-house. This produces the same air tangential fanchanges as a whole house fan yet requires a fraction of the air flow. The lower air flow and the use of tangential blowers makes the unit significantly quieter than a whole-house fan. The fan power is also a fraction of a whole house fan resulting in energy savings even when multiple fans are installed in a home.
Simple Installation – No holes to the attic – No Installation cost
The Eco Breeze installation is simple and can be done in minutes. It installs in a window and does not require cutting holes to access an attic, the addition of attic ventilation openings or the addition of electrical wiring.
Automated Operation – No windows to open and close
Eco Breeze exhausts the hot air to the outdoors and also brings the cool air into a room. The louvers automatically open to provide cooling and automatically close to seal the cool air inside ending the daily routine of opening and closing windows.
Seamless integration with air conditioning – No need to turn off the air conditioner
Eco Breeze monitors the indoor temperature and humidity and will only bring in the outside air if it is lower in temperature and humidity. The air conditioner thermostat will sense the cooler air and keep the air conditioner off.
Optimum use of Fresh Air Cooling – No more guessing
Eco Breeze has a dynamic temperature and humidity sensing system that automatically uses outside fresh air for cooling any time that it is available. In midsummer fresh air cooling may be available for a few hours a day in the late night and early morning in even the hottest regions. Eco Breeze will automatically save money even when you are sleeping. In the other seasons, Eco Breeze can operate mornings, evenings, and nights, and sometimes sizeable parts of the daytime.
Rain Guard System – No wet floors
Eco Breeze has a unique rain guard to prevent rain from blowing into your room even when it is operating. This completely eliminates the hassle of closing windows during rain storms.
For further information please call 866-432-8123 or click on the below link:
Eco Breeze FAQ's http://www.houseneeds.com/learning-center/house-fans-ventilation-erv-hrv-hep-filters/eco-breeze-faq
Thursday, May 22, 2014
How To Solder Copper Pipes
Caution: Please read and understand all safety
information before attempting maintenance or repairs. Wear eye protection and
gloves when soldering pipes and when working with flux. Flux is a toxic
substance. Some equipment may rely on a cold water supply. Take appropriate
steps to shut down any equipment that may be adversely affected by shutting off
the water supply. Such equipment includes, but is not limited to, a boiler or
other heating system.
Step 5 - Apply acid-free
flux to both the outside of the male fitting and the inside of the female
fittin
Note: Because you are working with a flame, often in
a confined space, be aware of flammable materials near where you are working.
In some cases, you may need to set up a non-flammable heat shield between the
solder joint and flammable material nearby. Check with your local authority for
applicable codes about the work you wish to perform and the necessity of
permits before you begin your project.
When copper pipes are fitted together, there is a very small gap
between the two pieces. When the pipes are heated, and solder is touched to the
pipes, the solder melts and is drawn up into the gap through capillary action.
Once the gap is filled, and the heat removed, the solder forms a seal and makes
a watertight joint. Soldering pipes is easy once you get the hang of it. The
key is to recognize that you are heating the pipes, not the solder. The heated
copper melts the solder. Follow the steps in this guide and you should be able
to make watertight joints. It is recommended that you practice a few times on
some spare parts until you feel confident.
Step 1 - Remove all burrs from the inside and outside edges
of the pipe with a de-burring brush. Small burrs can result in
a variety of problems in the lifespan of the water supply system.
![]() |
| Step 1 |
Step 2 - Clean the
outside of the pipe. If the copper is not clean, the solder may not bond properly Clean
the outside of the copper pipe to a brilliant shine with a copper pipe cleaning
brush, or simply use steel wool or emery cloth. If the copper is not clean, the
solder may not bond properly and the joint may leak.
Step 3 -Clean the inside
of the female fitting
Step 4 -Clean the inside of the female fitting
in the same way as in step
![]() |
| Step 2 |
Step 6 - Apply acid-free flux to both the
outside of the male fitting and the inside of the female fitting. Flux further cleans the copper plus helps to prevent
oxidation as the pipe heats up. If the pipe becomes oxidized, the joint may
leak.
Step 7 - Join the two
pieces securely together Join the two
pieces securely together. Unroll about four inches of solder and straighten it.
You will use the roll or container as a handle when applying the solder. Light
the torch and apply the flame to the joint. Move the flame around to ensure
that you heat the pipe on the opposite side from you.
Step 8 - When the flux
begins to bubble and spit, touch the tip of the solder to the joint Once the joint will
take no more solder it will build up outside of the joint and begin to drip.
Care should be taken at this point. Disrupting a joint as it cools can result
in a dry joint also known as a leak. Once the joint has hardened, it can be
wiped. This is the part where experience/practice helps. Some people use a dry
rag, so the joint can be cleaned, but not cooled to the point, where it creates
a dry/leaky.
| Step 5 |
| Step 4 |
NOTES:
| Step 6 |
NOTES:
1) Always
check for leaks after the pipe has cooled.
2) If
you overheat the copper, it will oxidize and that prevents the solder from
bonding.
3) If
the joint leaks, you must open the joint, remove all the solder and start over
by cleaning the metal and applying flux. It may be easier to start over with
new fittings.
4) Always
use lead-free solder.
5) Make
sure the pipes are completely dry or it will interfere with the bonding of the
solder.
6) If
you cannot completely stop the flow of water from the pipe you are working on,
it may be impossible to heat the pipe hot enough. Take a wad of white bread
(without the crust) and stuff it into the pipe. This will hold the water back
for a minute or two. After that the bread will dissolve harmlessly in the pipe
and is easily flushed out.
7) Specialty
parts may have requirements to disassemble seals or other components. Please
read all instructions from each manufacturer.
8) When
sweating ball valves, it is best to point the flame away from the piece,
sweating the ball valve as quick as possible.
If
you use MAPP gas instead of propane, it burns much hotter and will heat the
copper very quickly compared to propane. If you are used to propane, practice
with MAPP before beginning work.
Please visit www.houseneeds.com for fittings
Please visit www.houseneeds.com for fittings
Tuesday, May 20, 2014
Tamarack Technologies Whole House Fan
Currently on sale while supplies last
By pulling heat out of your home with the Tamarack TTi-HV1600 Whole House Fan, cooler outside air is drawn into the home. The heated air is then pushed out of your home through the attic vents. With a Tamarack Attic Fan - not only will you be more comfortable - but you will save money on your air conditioning bills.
· Easy
Installation
· Automatic
· Quiet
· Economical
· Draft Proof
· No Maintenance
· UL/CUL Listed
· Three Year Warranty
· Made in the USA
Comes with automatic insulated motorized doors. Standard R Value is R 38 for models TTi-HV1600. The doors form an air tight seal between your ceiling and your attic. No BIG un-insulated hole in your ceiling like other traditional whole house fans!
HV Whole House Sizing Chart
Standard 1 or 2 Story Home with summertime temperatures no warmer than 85 degrees F. summertime peak.
Up to 2,500 square feet use 1 - TTi-HV1600
2,500 to 3,000 square feet use 1 - TTi-HV1600 3,000 to
4,000 square feet use 2 - TTi-HV1600 or 2 - TTi-HV1600
4,000 to 5,000 square feet use 3 - TTi-HV1600 or 2 - TTi-HV1600
Standard 1 or 2 Story Home with summertime temperatures no warmer than 95 degrees F. summertime peak.
Up to 1,500 square feet use 1 - TTi-HV1600
1,500 to 2,500 square feet use 1 - TTi-HV1600
2,500 to 4,000 square feet use 2 TTi-HV1600 or use 2 - TTi-HV1600
4,000 to 5,000 square feet use 3 TTi-HV1600
Please call us at 866-432-8123 or 802-583-2726 if you have any questions or if you would to place an order or visit our website at www.houseneeds.com.
Thursday, May 8, 2014
Takagi Tankless Water Heater Outdoor Units
The flow rate and capacity of tankless water heaters depends on the temperature difference between the desired output and the incoming water temperatures. The condensing units are more energy efficient.
The Takagi T-KJr2-OS heater is the smallest gas water heater in the Takagi tankless line and is the same as the T-KJr-IN, but for outdoor installation only (Moderate temperature climates). The T-KJr-OS has gas inputs up to 140,000 BTU per hour - can meet all the hot-water needs of a small American home or apartment with one or two bathrooms. The T-K Jr2 OS has an energy factor of 81% to 83%. At an average (rise in temperature) of 60 Degrees F in warmer areas where the winter ground water is 60 Degrees F and with the output set at 120 Degrees F the unit will provide 3.8 GPM, or 228 GPH. The All new T-KJr2-OS has a max GPM of 6.6GPM.
The Takagi T-K4-OS is a mid-sized gas water heater in the Takagi tankless line and is the same as the T-K4-IN, but for outdoor installation only (Moderate temperature climates). The T-K4-OS has gas inputs up to 190,000 BTU per hour - can meet all the hot-water needs of your home, business or condo with one or two bathrooms. The T-K 4 OS has an energy factor of 81% to 83%. At an average (rise in temperature) of 60°F in warmer areas - where the winter ground water is 60°F and with the output set at 120°F - the unit will provide 5.2 GPM. The All new T-K4-OS has a max GPM of 8.0 gmp.
The Takagi T-D2-OS model was specifically designed for light commercial applications in outdoor locations. The Takagi Tankless Water Heater T-D2-OS offers a max flow rate of 10.0 GPM. The four preset temperatures on the unit are: 104°F, 113°F, 122°F, 131°F, 140°F, 158°F, 176°F and 185°F. To achieve any temperatures other than those presets, you will require the TK-RE30 temperature controller, which is included with the T-D2-OS.
The Takagi T-H3-OS is a high efficient, condensing tankless water heater perfect for residential and light commercial applications. With gas inputs of 199,000 BTU, the T-H3-OS-P can produce enough hot water for four bathrooms in warmer climates or three baths in colder climates. Primary heat exchanger utilizes HRS35 commercial-grade copper alloy for 25 times better heat transfer than stainless steel. Secondary heat exchanger utilizes 316L stainless steel for better corrosion resistance. Outdoor model includes remote control as standard feature
The Takagi T-H3S-OS is a high efficient, condensing, tankless water heater perfect for residential applications. With gas inputs of 180,000 BTU, the T-H3S-OS can produce enough hot water for three bathrooms in warmer climates or two baths in colder climates. Primary heat exchanger utilizes HRS35 commercial-grade copper alloy for 25 times better heat transfer than stainless steel. Secondary heat exchanger utilizes 316L stainless steel for better corrosion resistance. Outdoor model includes remote control as standard feature
The Takagi T-H3J is a high efficient, condensing tankless water heater perfect for residential applications. With gas inputs of 160,000 BTU, the T-H3J can produce enough hot water for two bathrooms in warmer climates or 1.5 baths in colder climates.
To compare products click here.
Please note Takagi Outdoor units are to be installed in mild climates only or for summer use only in colder climates.
Please call us if you have any further questions at 866-432-8123 or 802-583-2726.
The Takagi T-KJr2-OS heater is the smallest gas water heater in the Takagi tankless line and is the same as the T-KJr-IN, but for outdoor installation only (Moderate temperature climates). The T-KJr-OS has gas inputs up to 140,000 BTU per hour - can meet all the hot-water needs of a small American home or apartment with one or two bathrooms. The T-K Jr2 OS has an energy factor of 81% to 83%. At an average (rise in temperature) of 60 Degrees F in warmer areas where the winter ground water is 60 Degrees F and with the output set at 120 Degrees F the unit will provide 3.8 GPM, or 228 GPH. The All new T-KJr2-OS has a max GPM of 6.6GPM.
The Takagi T-K4-OS is a mid-sized gas water heater in the Takagi tankless line and is the same as the T-K4-IN, but for outdoor installation only (Moderate temperature climates). The T-K4-OS has gas inputs up to 190,000 BTU per hour - can meet all the hot-water needs of your home, business or condo with one or two bathrooms. The T-K 4 OS has an energy factor of 81% to 83%. At an average (rise in temperature) of 60°F in warmer areas - where the winter ground water is 60°F and with the output set at 120°F - the unit will provide 5.2 GPM. The All new T-K4-OS has a max GPM of 8.0 gmp.
The Takagi T-D2-OS model was specifically designed for light commercial applications in outdoor locations. The Takagi Tankless Water Heater T-D2-OS offers a max flow rate of 10.0 GPM. The four preset temperatures on the unit are: 104°F, 113°F, 122°F, 131°F, 140°F, 158°F, 176°F and 185°F. To achieve any temperatures other than those presets, you will require the TK-RE30 temperature controller, which is included with the T-D2-OS.
The Takagi T-H3-OS is a high efficient, condensing tankless water heater perfect for residential and light commercial applications. With gas inputs of 199,000 BTU, the T-H3-OS-P can produce enough hot water for four bathrooms in warmer climates or three baths in colder climates. Primary heat exchanger utilizes HRS35 commercial-grade copper alloy for 25 times better heat transfer than stainless steel. Secondary heat exchanger utilizes 316L stainless steel for better corrosion resistance. Outdoor model includes remote control as standard feature
The Takagi T-H3S-OS is a high efficient, condensing, tankless water heater perfect for residential applications. With gas inputs of 180,000 BTU, the T-H3S-OS can produce enough hot water for three bathrooms in warmer climates or two baths in colder climates. Primary heat exchanger utilizes HRS35 commercial-grade copper alloy for 25 times better heat transfer than stainless steel. Secondary heat exchanger utilizes 316L stainless steel for better corrosion resistance. Outdoor model includes remote control as standard feature
The Takagi T-H3J is a high efficient, condensing tankless water heater perfect for residential applications. With gas inputs of 160,000 BTU, the T-H3J can produce enough hot water for two bathrooms in warmer climates or 1.5 baths in colder climates.
To compare products click here.
Please note Takagi Outdoor units are to be installed in mild climates only or for summer use only in colder climates.
Please call us if you have any further questions at 866-432-8123 or 802-583-2726.
Tuesday, April 8, 2014
Electro Industries Repair Parts
Houseneeds sells Electro Industries Repair Parts for Electric Boilers and HVAC Products. Click on the Electro category to view parts.
Electro Parts Circuit Breakers Electro Parts Control Boards
Electro Repair Parts Elements Electro Parts Vessel Assembly
Electro Parts Relays and Cables Electro Parts Wiring Harnesses
Electro Parts Micro Chips Electro Parts Sensors
Electro Parts Reset Limits Electro Parts Electrical
Electro Parts Miscellaneous
We can not offer technical help with selection of any Electro Industries Repair Parts - please check you manual for help or contact Electro Industries Directly at 800.922.4138.
If you don't see the Electro Part on our site - first try the search on the top of every page to find the part before you call us.
Electro Parts Circuit Breakers Electro Parts Control Boards
Electro Repair Parts Elements Electro Parts Vessel Assembly
Electro Parts Relays and Cables Electro Parts Wiring Harnesses
Electro Parts Micro Chips Electro Parts Sensors
Electro Parts Reset Limits Electro Parts Electrical
Electro Parts Miscellaneous
We can not offer technical help with selection of any Electro Industries Repair Parts - please check you manual for help or contact Electro Industries Directly at 800.922.4138.
If you don't see the Electro Part on our site - first try the search on the top of every page to find the part before you call us.
Monday, March 31, 2014
Houseneeds Sells Embassy Boiler Repair Parts
Embassy Ambassador Axia Boilers Repair Parts
Buy Repair Parts for your AXIA Natural Gas Boiler and Propane Boilers.
Click here to order Axia parts on our website.
Embassy Ambassador BMS Boilers Repair Parts
Buy Repair Parts for your BMS Natural Gas Boiler and Propane Boilers.
Click here to order BMS parts on our website.
Embassy Ambassador Condensing Boiler Onex Repair Parts OX-160C OX-160B
Buy Repair Parts for Onex OX-160C and OX-160B Boilers.
Click here to order Onex parts on our website.
If you need a part that is not listed for your unit - please give us a call with the part number and we can try to get it for you. We can be reached at 802-583-2726 or toll-free at 866-432-8123.
Mestek Embassy Axia, BMS and Onex Combination Condensing Boilers Repair Parts are non-returnable.
Click here to order Axia parts on our website.
Embassy Ambassador BMS Boilers Repair Parts
Buy Repair Parts for your BMS Natural Gas Boiler and Propane Boilers.
Click here to order BMS parts on our website.
Embassy Ambassador Condensing Boiler Onex Repair Parts OX-160C OX-160B
Buy Repair Parts for Onex OX-160C and OX-160B Boilers.
Click here to order Onex parts on our website.
If you need a part that is not listed for your unit - please give us a call with the part number and we can try to get it for you. We can be reached at 802-583-2726 or toll-free at 866-432-8123.
Mestek Embassy Axia, BMS and Onex Combination Condensing Boilers Repair Parts are non-returnable.
Thursday, March 27, 2014
Houseneeds sells Bosch and Takagi tankless water heater repair parts
Please find the links listed below to where you can purchase the Bosch and Takagi repair parts on our Houseneeds website.
Click here to find Takagi parts
Click here to find Bosch parts
We only have the Bosch retail models listed at this time. However many of the parts for the Bosch retail models will fit the Bosch wholesale models. Type the part number in the search box (with no spaces) and click on the link to find your part on that page. Some of the parts that BBT (BOSCH) has are not listed on our site but can be special ordered from BBT. So if you do not find the part - please have the part number(s) that BBT gave you and then give us a call at 802-583-5501 to talk to a Houseneeds, Inc. Parts Representative.
Click here to find Takagi parts
Click here to find Bosch parts
We only have the Bosch retail models listed at this time. However many of the parts for the Bosch retail models will fit the Bosch wholesale models. Type the part number in the search box (with no spaces) and click on the link to find your part on that page. Some of the parts that BBT (BOSCH) has are not listed on our site but can be special ordered from BBT. So if you do not find the part - please have the part number(s) that BBT gave you and then give us a call at 802-583-5501 to talk to a Houseneeds, Inc. Parts Representative.
Monday, March 10, 2014
The MYSON iVECTOR
The MYSON iVECTOR is latest product innovation and an exciting, energy efficient addition to our range of modern heating solutions.
The Myson iVECTOR is the first in a new generation of intelligent fan convectors. It has been designed specifically to combine all the traditional advantages of a fan convector with a range of new product features made possible by our latest energy efficient heating technology. Overall, the iVECTOR provides an exciting package of significant benefits.
Myson iVector iV60X80-2 Heater / Cooling Fan Convector Techs and Specs
* Btu Heating 3791 to 14874
* Btu Cooling 2421 to 5623
* Fan Speed 3 - Normal / Medium / Boost
* Sound Levels 24.8 / 37.7 / 47.9
* Automatic and manual options for control of fan speeds
* Option to link to building management systems
* Night set-back function
* Programs saved in memory for 12 hours in event of power failure
To watch a video about this unit click here. Please call us if you have questions and if you would like to place an order at 866-432-8123.

Myson iVector iV60X80-2 Heater / Cooling Fan Convector Techs and Specs
* Btu Heating 3791 to 14874
* Btu Cooling 2421 to 5623
* Fan Speed 3 - Normal / Medium / Boost
* Sound Levels 24.8 / 37.7 / 47.9
· * Piping 2 Pipe or 4 Pipe models
* 3 year product warranty / 10 year warranty for the heat exchanger
Myson iVector iV60X80-2 Heater / Cooling Fan Convector Feature
· * Each iVECTOR is individually programmable
* 24/7 programmer with 1 hour time periods
* Lockable LCD backlit display * Automatic and manual options for control of fan speeds
* Option to link to building management systems
* Night set-back function
* Programs saved in memory for 12 hours in event of power failure
To watch a video about this unit click here. Please call us if you have questions and if you would like to place an order at 866-432-8123.

Tuesday, February 25, 2014
Biasi 3 Wood Cast Iron Boiler
Biasi Wood Boiler 3 Pass Technology with Btu output of up to 120,000 -
ASME certified and ETL approved
The Biasi 3WOOD is a new generation of wood boiler that challenges our oil dependency. It is efficient, easy to use, and produces low emissions.
Unlike wood boilers from the past, the Biasi 3WOOD dispels the notion that wood boilers are labor intensive, inefficient and polluting. 3WOOD offers consistent high efficiency with a large heat exchange surface and secondary combustion chamber.
The Biasi 3WOOD wood boilers water-cooled grates, large finned firebox and secondary combustion chamber maximize the burn time and minimize wood consumption. Easy adjustments to the automatic temperature control, secondary air regulator, and flue gas damper enhance fire maintenance. For over 70 years, the BIASI foundry has maintained a reputation for precision pressure castings and quality control that exceeds all international standards. The 3WOOD series is available in four sizes ranging from 89,000 to 120,000 BTU/HR. All threads and fittings are compatible with North American controls and accessories. 3WOOD, the only ASME certified and ETL approved cast iron wood boiler on the market, embodies the design innovation of QHT BIASI.
Biasi 3Wood Cast Iron Boiler Benefits & Features:
Biasi 3Wood Cast Iron Boiler - 89,000 - 104,000 - 120,000 Btu
For pricing click here
Biasi Wood Boiler - 3Wood Techs and Specs
Biasi 3Wood Boiler PDF Manuals
Call us if you have any questions at 866-432-8123 or 802-583-2726.
Tuesday, February 11, 2014
Designing a new heating system- Ask us
We very rarely
find that a system we set up for one client will work in its entirely for
another. We work with our clients to keep our systems simple and cost
effective. If you would like us to help you design a system there are a few
things we will need to know. To help us with your design, please read all of
the material below.
Any floor plans with square footage highlighted, can be e-mailed to sales@houseneeds.com, faxed (802-583-2572) or mailed ahead of time will help greatly to speed up your Quote.
4805 Main St
Waitsfield , VT 05673
The best way is to do a heat loss you can go to the below link to help you compute one for your project...
When you have
your information assembled please give me a call Toll Free at 1-866-432-8123 or
email sales@houseneeds.com or you can start by filling out some information at
Custom Heating, Solar or Radiant Heating Systems - Click Here!
Any floor plans with square footage highlighted, can be e-mailed to sales@houseneeds.com, faxed (802-583-2572) or mailed ahead of time will help greatly to speed up your Quote.
HouseNeeds
Inc. Attn: Sales
1. Please include the square footage of the areas
(zones) to be heated and not just the outside dimensions of the areas.
2. We will also need to know your desired type
of radiant installation method. Different methods are Slab on Grade, Thin pour
over concrete, Thin pour over wood, Staple up, Hung method, Heat Transfer Plates,
Thermal Board or another form installation. (If you need help deciding we can
help you after we have a set of your floor plans.)
3. A simple floor plan is all that is needed.
The floor plans do not need to be intricate. Simple line drawings on graph
paper work well.
4. A brief description of the number of windows and doors.
Please include wall and ceiling insulation values if known.
5. Please review
the entire e-mail, as there are links below to heat sources, hydronics and
radiant materials.
The best way is to do a heat loss you can go to the below link to help you compute one for your project...
Custom Heating, Solar or Radiant Heating Systems - Click Here!
Friday, February 7, 2014
Electro Warmflo Temperature Sensing Boiler with Dual Fuel
The Electro Electro-Boiler Midsize "MA, MO" Series is the most deluxe model that is designed for multiple temperature and zoning applications. This model has the ability to sense water temperature and maintain an accurate boiler temperature output by only energizing the electric elements for needed output (not full capacity). To learn more about this concept read WarmFlo. This model eliminates extra costs associated with relays, extra temperature controls, zone boxes, etc. Our more experienced installers use this boiler to avoid the extra cost of the above.
Our front panel temperature knob allows you to simply dial in your desired output temperature and the TS will automatically adjust to meet your water temperature needs. Available in 10-20 kW, single phase 240V.
Other Benefits
Available Literature/
Electro-Boiler Warranty Statement
Available Models:
240V single phase, w/ temperature setting dial, no outdoor reset
|
Model#
|
kW
|
Btu/h
|
Amps
|
Breakers
|
EB-MA-10
|
10
|
34,000
|
42
|
60
|
EB-MA-15
|
15
|
51,000
|
63
|
60,30
|
EB-MA-20
|
20
|
68,000
|
83
|
60,60
|
240V single phase, w/ temperature setting dial, outdoor reset
|
Model#
|
kW
|
Btu/h
|
Amps
|
Breakers
|
EB-MO-10
|
10
|
34,000
|
42
|
60
|
EB-MO-15
|
15
|
51,000
|
63
|
60,30
|
EB-MO-20
|
20
|
68,000
|
83
|
60,60
|
Other Benefits
- Built-in temperature/pressure gauge
- High Mass/Low Mass element modulation
- Boiler status panel
- ASME/CSA US/Canada certification
- Complete front panel accessibility
- Dual Boiler option
- Load Management connection
- Super quiet operation
- 20-year element/vessel warranty
Available Literature/
Specification Sheets
| BL002 | Radiant Applications |
| BL006 | Electro-Boiler Literature |
| BL509 | TS Series Midsize Specification Sheet |
Subscribe to:
Posts (Atom)



